Gasification Boilers PDF Print E-mail

Gasifying Boilers for Wood WoodGasificationBoiler_1_.gif

If you have timber freely available why pay for Oil or Gas to heat your home. This boiler will heat your home for less. very easy to use and there is a €2,000 SEI grant available for these units.

CLICK HERE OR MORE INFORMATION>>>>>

 


The boilers are constructed for burning wood on the principle of generator gasifying with the use of a gas exhaust ventilator, which withdraws the combustion gases from the boiler, or leads air into the boiler.

The boiler body is produced as a weldment of 3-8 mm steel sheets. They comprise the fuel hopper, which is equipped at the bottom with a heatproof pipe fitting with longitudinal hole for the combustion gases and passage of gases. The burnout part of the multiple chamber furnace under the fuel hopper is equipped with ceramic pipe fittings. There is a vertical combustion gas duct in the back of the boiler body, which is equipped with a heating valve in the upper section. The upper part of the combustion gas duct is fitted with a gas exhaust outlet for connection to a chimney.

We also stock a combined boiler for use with pellet and wood

ENVIRONMENT

Reverse combustion and a ceramic combustion chamber enable perfect combustion with minimum polluting emissions. The boilers comply with environmentally-friendly product requirements according to Guideline No. 13/2002 of the Czech Ministry of Environment. They comply the European Standard EN 303-5 and all the boilers rate in class 3

 

INSTALLATION

ATMOS boilers must be connected via the LADDOMAT 21 or ESBE thermoregulation valve to achieve keeping the minimum temperature of water returning to boiler at 65°C. The temperature of water exiting the boiler must be permanently kept between 80º - 90°C. The default configuration of all boilers includes a cooling circuit to prevent overheating. We recommend installing boilers with accumulation tanks.

CERTIFICATION

All ATMOS boilers are certified in testing laboratories for the individual countries of destination: State Testing Laboratory Brno, TÜV Munich - Germany, Lithuania, Ukraine, Sweden, Poland, Austria, Slovakia, Hungary according to current standards - EN 303-5.

Protected by patent.


Advantages of Wood Gasification Boilers ATMOS:

* Option to burn large pieces of wood
* Primary and secondary air is also preheated to a high temperature -    higher effectiveness
* The ventilator automatically switches off when the fuel but out.
* Ceramic combustion space - high effectiveness
* Large fuel container
* Large space for ash (when burning wood you have to clean it once per    week)
* Boiler without tube plate - easier cleaning
* Small size and low weight
* High quality

If you require any further information about our range of wood gasification products please contact us.


 

Click Here for more info >>>>


 



  •  



  •  
    Recommended configurations of installation with Laddomat 21, termoregulatory valves, electroregulation 3 ways mixing valve, electronical regulation of the heating system and heating of DHW in range up to 100kW.
  •  
  •  
  • 1. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 3 adding thermoregulators
    2. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 2 adding thermoregulators
    3. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 3 adding thermoregulators
    4. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, closed expansion vessel, easy installation with 2 adding thermoregulators
    5. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation
    6. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation
    7. Installation of boiler with 3 ways mixing valve, one heating circuit for DHW in combination boiler, opened expansion vessel, installation with electronic regulation
    8. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, opened expansion vessel, easy installation with 1 adding thermoregulator
    9. Installation of boiler with Laddomat 21, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation
    10. Installation of boiler with termoregulation mixing valve, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation
    11. Installation of boiler with 3 ways mixing valve, two heating circuits, one for DHW in buffer tank with solar coil, closed expansion vessel, installation with electronic regulation
    13. Installation of boiler with Laddomat 21, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, easy installation with 2 adding thermoregulators
    14. Installation of boiler with termoregulation mixing valve, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, easy installation with 2 adding thermoregulators
    15. Installation of boiler with 3 ways mixing valve, one heating circuit for DHW in combination boiler, buffer tank, closed expansion vessel, installation with electronic regulation
    16. Installation of boiler with Laddomat 21, two accumulation tanks, heating of DHW in buffer tank, one heating circuit, closed expansion vessel, installation with electronic regulation
    17. Installation of boiler with 3 ways mixing valve, two accumulation tanks, heating of DHW in buffer tank, one heating circuit, closed expansion vessel, installation with electronic regulation
    18. Installation of boiler with Laddomat 21, two accumulation tanks, two heating circuits, one for DHW in combination boiler, opened expansion vessel, installation with electronic regulation
    19. Installation of boiler with Laddomat 21, three accumulation tanks, two heating circuits, heating of DHW in buffer tank, closed expansion vessel, easy installation with an adding thermoregulator
    20. Installation of boiler with Laddomat 21, three accumulation tanks, two heating circuits, heating of DHW in buffer tank, closed expansion vessel, installation with electronic regulation
    21. Installation of boiler with Laddomat 21, one accumulation tank, three heating circuits one for DHW in combination boiler, closed expansion vessel, installation with electronic regulation
    22. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve
    23. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve
    24. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve
    25. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve
    26. Installation of two boilers with Laddomat 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve
    27. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, two heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the two boilers by 3 ways mixing valve
    28. Installation of two ATMOS boilers, with 3 ways mixing valves, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve
    29. Installation of two ATMOS boilers, with termoregulation mixing valves, two heating circuits, one for DHW in combination boiler, closed expansion vessels, buffer tank min. 1000l, easy installation with adding thermoregulators, possible to heat by both boilers at the same time
    30. Installation of two boilers with Laddomats 21, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators
    31. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, installation with electronic regulation, switching the two boilers by zone valves
    32. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, easy installation with adding thermoregulators, switching the two boilers by zone valves
    33. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessel, easy installation with adding thermoregulators, switching the two boilers by zone valves
    34. Installation of two boilers with Laddomat 21 for keeping the temperature of returning water to the both of the boilers at 65°C, buffer tank, two heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by 3 ways mixing valve
    35. Installation of two boiler, one with Laddomat 21, heating of DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the two boilers by zone valves
    36. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, buffer tank, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves
    37. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves
    38. Installation of three boilers, each with 3 ways electronic mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators
    39. Installation of three boilers, each with termoregulation mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation, switching the three boilers by zone valves
    40. Installation of three boilers, each with Laddomat 21, three heating circuits, one for DHW in combination boiler, buffer tank, closed expansion vessels, installation with electronic regulation, switching the three boilers by zone valves
    41. Installation of three boilers, each with 3 ways electronic mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, installation with electronic regulation
    42. Installation of three boilers, each with termoregulation mixing valve, three heating circuits, one for DHW in combination boiler, closed expansion vessels, easy installation with adding thermoregulators, switching the three boilers by zone valves